19/11/2017 3:20 PM


 

Product image
Item name Price
  AC1 sensor
 

AC1 sensor

Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C
price on request

min 20 pcs

Description
Datasheet

Reference electrode is made of Ag/AgCl or silver and conductive paths are made of silver. Working (1 mm or 2 mm diameter) and counter electrode is made of alloy of Au/Pt, pure Au, pure Pt, pure Ag or graphite. The active parts are covered by a dielectric protection layer. This type of sensor is widely used for basic electrochemical analysis in environmental, clinical or agri-food areas. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor. 

 AC1 datasheet

Device arrangement

 
Product image Item name Price
  
MAC

MAC sensor

Microreactor for sensor used for measurement of small volume (20 µl) in closed system.

Dimensions: 7.26 (width) x 0.63 mm (thickness)

WE material: Au/Pt, Au, Pt, Ag, C

price on request

min 20 pcs

Description Datasheet

Small microreactor with lid which is integrated on the sensor. It create disposable electrochemical unit comparable with classical macrocell. Microreactor MAC can be used for placing analyte exactly on the active part of the sensor with width 7.26 mm (AC1, AC13, AC13S, CC1).

 MAC datasheet

Device arrangement

 
Product image Item name Price
  
 AC1.AChe

AC1.AChE sensor

Amperometric Acetylcholinesterase three-electrode sensor with patented structure made by thick film technology

Dimensions: 25.4 x 7.26 x 0.63 mm 

WE material: Pt

price on request

min 25 pcs

Description Datasheet

Acetylcholinesterase (AChE) from electric eel type VI-S is immobilized on the active surface of electrochemical sensor AC1.W2.RS. The diameter of the immobilized bioactive membrane is 2 mm and the mean applied activity is 1 unit/mm2. The sensor is used for measurement of AChE inhibitor concentration (organophosphorous and carbamate pesticides, toxic and neurotoxic gases,...).

 AC1.AChE datasheet

Device arrangement

 
Product image Item name Price
  AC1.GOD
 

AC1.GOD sensor

Amperometric Glucose Oxidase three-electrode sensor with patented structure made by thick film technology

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Pt

price on request

min 25 pcs

Description Datasheet

Glucose Oxidase (GOD) from Aspergillus Niger is immobilized on the active surface of electrochemical sensor AC1.W2.RS. The diameter of the immobilized bioactive membrane is 2 mm and the mean applied activity is 1 unit/mm2. The sensor is used for measurement of glucose concentration.

References: Long term stability

 AC1.GOD datasheet

Device arrangement

 
Product image Item name Price
  AC1P sensor
 

AC1P sensor

Amperometric three-electrode sensor with patented structure type AC1 with polished working electrode made by thick film technology.  

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Au


price on request

min 5 pcs

Description Datasheet

Working electrode has homogenous surface with roughness less than 1 µm.  The sensor is used for measurement of basic electrochemical and bio-electrochemical techniques such as H2O2 concentration, Glucose, Ferricyanide, Trace analysis (e.g. stripping voltammetry), Toxicity caused by pesticides,  Enzyme activity and Michaelis Menten constant or Immobilization of antibodies or preparation of nanostructures.

 AC1P datasheet

Device arrangement

 
Product image Item name Price
  AC2 sensor
 

AC2 sensor

Amperometric two-electrode sensor with two working electrodes made by thick film technology.

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

price on request

min 20 pcs

Description Datasheet

An electrochemical sensor with 2 working electrodes and 1 reference electrode allowing differential measurement of two signals at once. The sensor is used for basic electrochemical and bio-electrochemical techniques, it enables the measurement of 2 species simultaneous or analysis on background of electrochemically active compound (electrochemical interference). Sensor can be used for immobilization of antibodies or preparation of nanostructures.

 AC2 datasheet

Device arrangement

 
Product image Item name Price
AC3 sensor
 

AC3 sensor

Narrow amperometric single working electrode sensor made by thick film technology

Dimensions: 50.8 x 2.54 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 price on request

min 20 pcs

Description Datasheet

A narrow single working electrode sensor designed to replace metal electrodes made from expensive materials. Sensor can be used for immobilization of antibodies or preparation of nanostructures and measurement in narrow vessels.

 AC3 datasheet

                     

 
Product image Item name Price
  AC4 sensor
 

AC4 sensor

Amperometric single working electrode sensor with an extremely big working electrode made by thick film technology

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 
price on request

min 5 pcs 

Description Datasheet

A single working electrode sensor with an extremely big metal surface area. The sensor is used as a low cost auxiliary (working) electrode for basic electrochemical measurement. It can be used in corrosion measurement or in fuel cells or biofuel cells applications.

 AC4 datasheet

Device arrangement

 
Product image Item name Price
  AC5 sensor
 

AC5 sensor

Screen printed electrochemical array of 8 working electrodes

Dimensions: 25.4 x 50.8 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 price on request

min 5 pcs

Description Datasheet

The working electrodes create an array of 8 working electrodes.  Each electrode has its own reference electrode.  It is possible to measure eight signals at once. Particularly used for the multiple simultaneous analysis (electrochemical immunoassay). Sensor can be used for immobilization of antibodies or preparation of nanostructures.

 AC5 datasheet

                       

 
Product image Item name Price
  AC6 sensor
 

AC6 sensor

Amperometric  three-electrode sensor with two auxiliary electrodes made by thick film technology

Dimensions: 25.4 x 10.16 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 price on request

min 20 pcs

Description Datasheet

An electrochemical sensor with 1 working, 1 reference and 2 auxiliary electrodes. Sensor can be used for immobilization of antibodies or preparation of nanostructures. The auxiliary electrode can be used for electrochemical generation of reactant.

 AC6 datasheet

Device arrangement

 
Product image Item name Price
  AC7 sensor
 

AC7 sensor

Amperometric three-electrode shorter version of AC1 made by thick film technology

Dimensions: 12.7 x 7.26 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 price on request

min 20 pcs 

Description Datasheet

This sensor is a shorter version of the AC1.  It is intended for a different connector with soldered pins. The sensor is used for measurement of basic electrochemical and bio-electrochemical techniques such as H2O2 concentration, Glucose, Ferricyanide, Toxicity caused by pesticides, Enzyme activity and Michaelis Menten constant. Can be used for immobilization of antibodies or preparation of nanostructures. It was originally used with diffusion cell to detect chemicals in air.

 AC7 datasheet

                       

 
Product image Item name Price
  AC8 sensor
 

AC8 sensor

Amperometric sensor with 4 working electrodes made by thick film technology

Dimensions: 50.8 x 8.47 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 price on request

min 10 pcs

Description Datasheet

An electrochemical sensor with 4 working electrodes. They can be modified by enzyme, DNA, antibody, etc. for multi-analyte detection. This specific range of AC8 sensors enables the measurement of four independent species (modified by enzyme, DNA, antibody, etc.) and multianalyte detection.

 AC8 datasheet

Device arrangement

 
Product image Item name Price
  AC9C sensor
 

AC9C sensor

Amperometric sensor with an array of 8 working electrodes and 1 common reference electrode made by thick film technology with integrated connector

Dimensions: 59.0 x 12.7 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

price on request

min 5 pcs

Description Datasheet

An electrochemical sensor with an array of 8 working electrodes and 1 common reference electrode.  It is used as a biosensor substrate for multi-analyte detection. An integrated connector is at the end of sensor. Different enzymes can be put on the working electrodes of the sensor.

 AC9C datasheet

                        

 
 
Product image Item name Price
  AC10 sensor
 

AC10 sensor

Amperometric  three-electrode sensor with an array of 20 working electrodes made by thick film technology

Dimensions: 50.8 x 12.7 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

price on request

min 5 pcs

Description Datasheet

An electrochemical sensor with an array of 20 working electrodes and 1 common reference electrode.  It is used for the complicated complex analysis of 20 analytes in one step. Different enzymes, antibodies or DNA probes can be applied on the working electrodes of the sensor.

 AC10 datasheet

Device arrangement

 
 
Product image Item name Price
  AC13 sensor
 

AC13 sensor

Amperometric  three-electrode longer version of AC1 made by thick film technology

Dimensions: 50.8 x 7.26 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 price on request

min 10 pcs

Description Datasheet

The sensor is used for measurement of basic electrochemical and bio-electrochemical techniques such as H2O2 concentration, Glucose, Ferricyanide. It is used for measurement of toxicity caused by pesticides, Enzyme activity and Michaelis Menten constant. Antibodies or DNA enzymes can be immobilized.

 AC13 datasheet

Device arrangement

 
 
Product image Item name Price
 AC13S 
 

AC13S sensor

Amperometric sensor integrates electrochemical three-electrode sensor with heating and thermometer  Pt100.

Dimensions: 54 x 16.16 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

  price on request

min 1 pc

Description Datasheet

This specific range of AC13S sensors enable the measurement and development of new analytical techniques where the mass transport is based on thermodiffusion. They can also be used for measurement of thermal optimum of immobilized enzymes, relaxation techniques in slow chemical reaction, measurement of chemical reaction activation energy, measurement of immobilized biochemical compounds activation energy, measurement with ionic liquids and measurements with viscous liquids.

 AC13S datasheet

Device arrangement

 
 
Product image Item name Price
  CC1 sensor
 

CC1 sensor

A conductivity sensor made by thick film technology with interdigitated structure of electrodes

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 price on request

min 20 pcs

Description Datasheet

The sensor is used for the measurement of basic electrochemical and bio-electrochemical techniques and conductivity analysis.

 CC1 datasheet

Device arrangement

 
 
Product image Item name Price
  
 CC2 sensor

CC2 sensor

A conductivity sensor with two active parts made by thick film technology with interdigitated structure of electrodes

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

price on request

min 20 pcs

Description Datasheet

A sensor designed for differential conductivity measurements of conductivity on the background of another effect. The sensor enables the measurement of small changes of conductivity at high background conductivity of supporting electrolyte.

 CC2 datasheet

Device arrangement

 
Product image Item name Price
  
 CC3

CC3 sensor

A conductivity sensor made by thick film technology with interdigitated structure of electrodes

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 price on request

min 20 pcs

Description Datasheet

The sensor is used for the measurement of basic electrochemical and bio-electrochemical techniques and conductivity analysis.

 CC1 datasheet

Device arrangement

 
 
Product image Item name Price
  TS sensor
 

TS sensor

Simple identificator of electrochemical hardware error

Dimensions: 25.4 x 7.26 x 0.63 mm

 

price on request

min 1 pc

Description Datasheet

Testing sensor enables simple identification of electrochemical hardware error. The sensor has same geometry as AC1 type but its response is produced by resistor.

 TS datasheet

                       

 
 
Product image Item name Price
  
 

STK.RDE sensor

Set of twenty electrochemical sensors to start your measurement with miniRDE.

price on request
Description Datasheet

Starting kit contains 8 types of electrochemical sensors, sensors connector KA1s.S and sensors box with numbered positions and silica gel.

 STK.RDE datasheet

                       

 
Product image Item name Price
  
 STK

STK.S

Set of twenty electrochemical sensors to find the best one to fit your application.

price on request
Description Datasheet

Starting kit contains 10 types of electrochemical sensors (2 sensors of each type), sensor connector KA1s.S and sensor box with numbered positions and silica gel.

 STK.S datasheet

Device arrangement

 
 Product image Item name Price
  
 Project sensors
Customer screen printed electrode

Customer screen printed electrode can be manufactured. BVT supplies sensors based on customer´s specifications.
 price on request
Description Datasheet

Customer screen printed electrode can be manufactured. BVT supplies sensors based on customer´s specifications. Price calculation includes design of screens and minimum serie of 100 sensors.

 Customer screen printed electrode

                            

For more information please contact:
Eng. Radka Kučerová

Eng. Radka Kučerová

Office Manager

E-mail: info (at) bvt.cz

Tel.: + 420 563 034 298                         

Hudcova 78c, 612 00 BRNO