  • AC1 Dwe= 4 mm Electrochemical sensor

    Basic amperometric three-electrode sensor with patented structure made by thick film technology.

     Dimensions: 38.10 mm after breaking off (25.40 mm) x 7.26 mm x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer.

     

    A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor. All sensors can be equipped with heating and temperature sensing elements. Thermistor (must be calibrated) or Pt 1000 (the response corresponds to the ISO standard) can be used as the temperature sensor. The sensor is equipped with handling part which enables safe manipulation without contamination of active area.

     

    The handling part can be broken off and sensor can be inserted in the standard BVT flow cells.

     

     

     

    We also offer:

    • working electrode made of polished gold (WE diameter 1 or 2 mm) – sensor type: AC1P.W*.R*, with homogenous surface with roughness less than 1 µm
    • working electrode made of a material of guaranteed purity of up to 99.99 % (WE diameter 2 mm) – sensor type: AC1.GP

    We also offer activated graphite sensors on customer request.

    See activation example below:

     

    * Have a look at product cathegory Discounted SPEs – which include offer of Screen Printed Electrodes (SPEs) at a reduced Price from our AC1 line of Sensors. They are fully functional, but with visual defects or inconsistancies.

    – ideal for use by students to gain handling experience and knowledge on SPEs and their uses
    – ideal for initial experiments in research

    Read more
  • AC1 Electrochemical sensor

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer.

     

    A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor. All sensors can be equipped with heating and temperature sensing elements. Thermistor (must be calibrated) or Pt 1000 (the response corresponds to the ISO standard) is used as the temperature sensor.

     

     

    We also offer:

    • working electrode made of polished gold (WE diameter 1 or 2 mm) – sensor type: AC1P.W*.R*, with homogenous surface with roughness less than 1 µm
    • working electrode made of a material of guaranteed purity of up to 99.99 % (WE diameter 2 mm) – sensor type: AC1.GP

    We also offer activated graphite sensors on customer request.

    See activation example below:

     

    * Have a look at product cathegory Discounted SPEs – which include offer of Screen Printed Electrodes (SPEs) at a reduced Price from our AC1 line of Sensors. They are fully functional, but with visual defects or inconsistancies.

    – ideal for use by students to gain handling experience and knowledge on SPEs and their uses
    – ideal for initial experiments in research

    Read more
  • AC1 Sw = 6.8 mm2 Electrochemical sensor

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer.

     

    A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor. All sensors can be equipped with heating and temperature sensing elements. Thermistor (must be calibrated) or Pt 1000 (the response corresponds to the ISO standard) is used as the temperature sensor.

     

     

    We also offer:

    • working electrode made of polished gold (WE diameter 1 or 2 mm) – sensor type: AC1P.W*.R*, with homogenous surface with roughness less than 1 µm
    • working electrode made of a material of guaranteed purity of up to 99.99 % (WE diameter 2 mm) – sensor type: AC1.GP

    We also offer activated graphite sensors on customer request.

    See activation example below:

     

    * Have a look at product cathegory Discounted SPEs – which include offer of Screen Printed Electrodes (SPEs) at a reduced Price from our AC1 line of Sensors. They are fully functional, but with visual defects or inconsistancies.

    – ideal for use by students to gain handling experience and knowledge on SPEs and their uses
    – ideal for initial experiments in research

    Read more
  • AC1.AChE Electrochemical sensor

    Amperometric Acetylcholinesterase three-electrode sensor with patented structure made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm 

    WE material: Pt

     

    Sensor Usage: Measurement of AChE inhibitor concentration – especially organophosphorous and carbamate pesticides (paraoxon, malaoxon), toxic and neurotoxic gases (sarin, soman, tabun, VX).

     

    Acetylcholinesterase from electric eel type VI-S is immobilized on the active surface of a working electrode of electrochemical sensor AC1.W2.RS (i.e. Platinum working electrode, silver reference electrode). The diameter of the immobilized bioactive membrane is 2 mm and the mean applied activity is 1 unit/mm2.

     

    * For this product, we recommend our customers use the Training Service from BVT.

    (https://bvt.cz/produkt/offer-of-long-term-automated-measurements-on-bvt-apparatus/)

    Read more
  • AC1.GOD Electrochemical sensor

    Amperometric Glucose Oxidase three-electrode sensor with patented structure made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Pt

     

    Sensor Usage: Amperometric measurement of β-D-Glucose concentration in liquid samples (from 0 °C to 45 °C)

     

    Glucose Oxidase (GOD) from Aspergillus Niger is immobilized on the active surface of a working electrode of amperometric substrate AC1.W2.RS.

    The diameter of the immobilized bioactive membrane is 2 mm and the mean applied activity is 1 unit/mm2.

     

    * For this product, we recommend our customers use the Training Service from BVT.

    (https://bvt.cz/produkt/offer-of-long-term-automated-measurements-on-bvt-apparatus/)

    Read more
  • AC1.GP. Electrochemical sensor with a working electrode of guaranteed purity

    Basic amperometric three-electrode sensor with patented structure made by thick film technology.

     

    Dimensions: 25.40 mm x 7.26 mm x 0.63 mm

    WE material: gold, platinum, silver, copper, iron, nickel, cobalt, chromium, tantalum, irridium, rhenium, magnesium, palladium, zirconium and others

     

    *Selection of sensor electrode materials other than those listed above is possible upon agreement with the customer.

     

     

    The sensor is made on a corundum ceramic base. Working, reference and auxiliary electrodes are applied to this surface. Working, reference and auxiliary electrodes are made of different materials. At the end of the sensor there is a contact field that is connected to the active part by silver conductive paths that are covered with a dielectric protective layer. The working electrode of the sensor with a diameter of 2 mm is made of a material of guaranteed purity of up to 99.99 % depending on the selected material– standard layer thickness 0.0125 mm.

     

     

    We also offer a working electrode made of polished gold AC1P.W*.R*, with homogenous surface with roughness less than 1 µm.

     

    We also offer activated graphite sensors on customer request.

     

    Read more
  • AC13 Electrochemical sensor

    Amperometric  three-electrode longer version of AC1 made by thick film technology

    Dimensions: 50.8 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

    Read more
  • AC1P Electrochemical sensor

    Amperometric three-electrode sensor with patented structure type AC1 with polished working electrode made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. Working electrode has homogenous surface with roughness less than 1 µm. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

    Read more
  • AC2 Electrochemical sensor

    Amperometric two-electrode sensor with two working electrodes made by thick film technology.

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface two working electrodes, and one reference electrode are applied. The working and the auxiliary electrodes can be made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. Different bio-chemically active substance can be immobilised on the working electrode to create a biosensor.

    Read more
  • AC3 Electrochemical sensor

    Narrow amperometric single working electrode sensor made by thick film technology

    Dimensions: 50.8 x 2.54 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working electrode is applied. The working electrode is made of variety of materials. At the end of the sensor there is a contact which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor.

    Read more
  • AC4 Electrochemical sensor

    Amperometric single working electrode sensor with a extremely big working electrode made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface working electrode is applied. The working electrode is made of variety of materials. At the end of the sensor there is a contact which is connected with the active part by the silver conducting path which is covered by a dielectric protection layer.

     

    Read more
  • AC5 Electrochemical sensor

    Screen printed electrochemical array of 8 working electrodes

    Dimensions: 25.4 x 50.8 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working and the reference electrodes are applied. The working electrodes create an array of eight electrodes. The electrodes can be made of variety of materials (see below). At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrodes of the sensor.

    Read more
  • AC6 Electrochemical sensor

    Amperometric  three-electrode sensor with two auxiliary electrodes made by thick film technology

    Dimensions: 25.4 x 10.16 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and two auxiliary electrodes are applied. The electrodes can be made from variety of materials (see below). At the end of the sensor there is a contacting field. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor.

    Read more
  • AC8 Electrochemical sensor

    Amperometric sensor with 4 working electrodes made by thick film technology

    Dimensions: 50.8 x 8.47 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface four working electrodes are applied. Electrodes are made of variety of materials (see below). At the end of the sensor there is a contact. It is connected with the active part by the silver conducting path which is covered by a dielectric protection layer. Different bio-chemically active substances can be immobilised on working electrodes of the sensor.

    Read more
  • AC9C Electrochemical sensor

    Amperometric sensor with an array of 8 working electrodes and 1 common reference electrode made by thick film technology with integrated connector

    Dimensions: 59.0 x 12.7 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface eight working electrodes, and the reference electrode are applied. The electrodes can be made of variety of materials (see below). At the end of the sensor there is an integrated connector. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. Different bio-chemically active substances can be immobilised on the working electrodes of the sensor.

    Read more
  • AC9C.WSP Electrochemical sensor

    Amperometric sensor with an array of 8 working electrodes and 1 common reference electrode made by sputtering with integrated connector

    Dimensions: 59.0 x 12.7 x 0.63 mm

    WE material: Au

     

    The sensor is formed on corundum polished ceramic base. On to this surface eight working electrodes, and the reference electrode are applied by sputtering. The working electrodes are made of gold. At the end of the sensor there is an integrated connector. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. Different bio-chemically active substances can be immobilised on the working electrodes of the sensor.

    Read more