  • Epsilon EClipse

    The Epsilon EClipse is the latest electrochemical analyzer manufactured by BASi.

     

    It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. Software with the most popular electrochemistry techniques is included with the instrument. 

     

    More information can be found through the link: https://www.basinc.com/epsilon/eclipse

     

    This System Includes:

    • Basic Software – techniques include
      • Cyclic Voltammetry/Linear Sweep Voltammetry
      • Chronoamperometry/Chronocoulometry
      • Controlled Potential Electrolysis
      • DC Potential Amperometry
      • Open Circuit Potential vs. Time
      • Chronopotentiometry
    • Basic Plus Software – techniques include
      • Sampled Current Polarography
      • Normal Pulse Voltammetry/Polarography
      • Differential Pulse Voltammetry/Polarography
      • Square Wave Voltammetry
      • Stripping Voltammetry Techniques
      • Double Potential Step Chronopotentiometry
    • Methods Software – techniques include
      • Prepare sequences with an unlimited number of techniques
      • Insert trigger and delays in sequence
      • Repeat sequence up to 9999 times
    • Bi-Potentiostat – techniques include
      • Multi-Channel Amperometry
      • Multi-Channel Cyclic Voltammetry 
      • Multi-Channel Chronoamperometry

    10’ USB Cable
    Bi-Potentiostat cell lead cable

     

    Specifications:

    Potentiostat

    • Channel 1 applied potential: Dynamic DAC: 16 bit, ±3.275 V @ 0.1 mV resolution or ±10 V @ 0.33 mV resolution
    • Offset DAC: 8 bit, ±2.55 V @ 10 mV resolution
    • Channel 2 applied potential: Dynamic DAC: 8 bit, ±2.55 V @ 10 mV resolution
    • Compliance voltage: ±12 V
    • Maximum current: 100 mA
    • Bandwidth: > 100 kHz
    • Bias current: < 1pA
    • Electrometer input impedance: > 1012W
    • (values for parameters other than applied potential are for both channels)

    Current-to-voltage converter

    • Full scale sensitivity: 1 nA*, 10 nA*, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA,100 mA, (*secondary gain used)
    • Secondary gain: x1, x10, and x100
    • ADC resolution: 16 bit
    • Sampling rate: 50 kHz (20 µs/conversion)
    • Data length: up to 64k points – fast

    Galvanostat

    • Applied current: 50 pA – 50 mA
    • Range: ±10 V ± 1 V
    • Measured potential resolution: 0.02 mV
    • Max leakage current: 30 pA

    I/O

    • Eout (applied potential)
    • Iout (current to voltage output)
    • Ein (input connection for external applied wave form)
    • Cell Stand port (control of C-3 Cell Stand and CGME)
    • Ordering Port (control of RDE-2)
    • PC (USB) port
    • Trigger out (TTL)

    Minimum PC requirements

    • Win 7 or higher
    • Pentium III
    • 512 MB RAM
    • 50 MB hard drive space available
    • USB port

    Power requirements

    • 120 or 240 VAC, 50/60 Hz, 60 VA

    Dimensions & weight

    • 15.75″ (40 cm) x 5.25″ (13 cm) x 12.75″ (32.5 cm)
    • 17.5 lb (7.4 kg) (1 channel)