Category: Glass Cells

Glass Cells

Showing all 10 results

  • Basic electrochemical cell setup (redox.me)

    This is a stationary solution basic electrochemical cell for measurements of electrodes in a form of:

    a) rod/disc (6 mm dia.),

    b) thin film deposited on a flat substrate (using a wire clip) and

    c) membrane (using a wire clip).

     

    The working, counter, and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (FKM/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. The cell chamber is available in several material variants here (glass, PTFE, PEEK)

     

    Application note:
    The reference electrode tip should be placed at the level of working electrode center. This will ensure a low potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including metal wire and metal foil electrodes as well as graphite rod. The bubbling of gas through the solution must be stopped prior to experiment.

     

    Specification:
    maximum electrolyte volume: 50 mL
    electrode plug diameter: 6 mm
    number of electrode slots: 3

     

    Intrastat data:
    HS Code: 90309000
    Country of Origin: Sweden
    NET weight: 200 g

     

    Setup includes:

    Item Qty B-A-BEC-50 B-O-BEC-50
    BEC 50 mL – Basic Electrochemical Cell 1 C-A-BEC-50 C-O-BEC-50
    Metal wire auxiliary electrode – 50HX15 0.6/250 mm, platinum (99,9%), 1 mm dia. gold plated pin 1 E-A-50HX15_Pt-1mm E-O-50HX15_Pt-1mm
    Silver / Silver Chloride Reference Electrode – Ag/AgCl 70 mm 1 E-Ag/AgCl_70  
    Non-aqueous Silver / Silver Ion Reference Electrode – Ag/Ag+ 70 mm 1   E-Ag/Ag+_70
    Working disk electrode – 2 mm dia., PEEK BODY 6 mm dia. – 70 mm, glassy carbon 1 E-A-DISK_GC-70 E-O-DISK_GC-70
    10 pcs of Tantalum wire clip with septum plug 0.6 mm dia., 60 mm long 1 E-A-Ta_CLIP-0.6/60-10p E-O-Ta_CLIP-0.6/60-10p
    Read more
  • Basic electrochemical H-cell setup (redox.me)

    This is a stationary solution double compartment electrochemical H-Cell for measurements of electrodes in a form of:

    a) rod/disc (6 mm dia.),

    b) thin film deposited on a flat substrate (using a wire clip) and

    c) membrane (using a wire clip).

     

    The working, counter and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. The counter electrode is placed in a compartment separated from the other electrodes by ion-exchange membrane (19 mm to 25 mm dia.), so the electrochemical products appearing at working and counter electrode do not affect the opposite electrode. The counter electrode compartment is equipped with a separate inlet and outlet for easy filling with an electrolyte and evacuation of gaseous products. It can accommodate standard Metal Wire Auxiliary Electrode as well as square shape electrodes with sizes up to 25 mm x 25 mm. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (FKM/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. After removal of the counter electrode glass compartment, the cell gets the functionality of a Basic Electrochemical Cell – BEC 50 mL

    The cell chamber is available in several material variants here.

     

    Application note:
    The reference electrode tip and working disk electrode tip should be placed in the middle of the membrane. This will ensure a low potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including metal wire and metal foil/mesh/foam electrodes as well as graphite rod. The bubbling of gas through the solution must be stopped prior to experiment. 

     

    Specification:
    minimum electrolyte volume in WE compartment: 22 mL
    minimum electrolyte volume in CE compartment: 6 mL
    maximum electrolyte volume: 40 mL
    minimum membrane diameter: 19 mm
    maximum membrane diameter: 25 mm
    maximum membrane thickness: 0.5 mm
    electrode plug diameter: 6 mm
    number of electrode slots: 3

     

    Intrastat data:
    HS Code: 90309000
    Country of Origin: Sweden
    NET weight: 200 g

     

    Setup includes:
    1 x BE H-Cell 50 mL – Basic Electrochemical H-Cell 50 mL
    1 x Metal Wire Auxiliary Electrode – 50HX15 0.6/250 mm (Platinum)
    1 x Reference electrode (Ag/AgCl, or Ag/Ag+)
    1 x Glassy Carbon disk electrode – 2 mm dia.
    1 x Plug with silicone rubber septum and set of Tantalum wire clips (set of 10)

    Read more
  • Bottom mount front contact electrochemical cell setup (redox.me)

    This is a static voltammetry cell with variants for different sample dimensions. The sample is loaded from the bottom via magnetic or screw mount, while counter or/and reference electrodes are mounted in the lid as either 2-, or 3-electrode configuration. The cell is constructed with materials that are inert to the sample environment (glass and PEEK), and it can be used with FKM/EPDM O-rings or FFKM O-rings for aqueous or organic electrolyte requirements, respectively. The construction is gas-tight and inert gas can be bubbled through the electrolyte to remove and exclude contaminants such as air or water.

     

    Application note:
    The reference electrode tip should be placed close to the sample surface to ensure a negligible potential drop throughout the electrolyte solution during low-current experiments. In the magnetic variant of the cell, the strength with which the magnets hold the sample is adjusted by adding or removing the washers under the magnets. Thanks to this procedure, the distance between the magnets changes, with it, the force of their attraction. Various auxiliary electrodes are suitable for this cell, including metal wire and metal plate electrodes as well as carbon-based electrodes (graphite or Glassy Carbon). If a purge gas is used, stop the flow during experiments for better results. 

     

    Specification:
    nominal exposure area: 0.07 cm2 for 5x5mm2, 0.2 cm2 for 7x7mm2, 0.5 cm2 for 10x10mm2, and 1.33 cm2 for 15x15mm2
    minimum electrolyte volume: 2.5 mL
    maximum electrolyte volume: 15 mL
    electrode plug diameter: 6 mm
    substrate size: 5x5mm2, 7x7mm2, 10x10mm2, and 15x15mm2, other sizes available on request
    minimum substrate thickness: 0.4 mm*

    *lower thicknesses are also feasible when using a pad below the sample

     

    Intrastat data:
    HS Code: 90309000
    Country of Origin: Sweden
    NET weight: 200 g

     

    Setup includes:
    1 x BM FC EC 15mL – Bottom Mount Front Contact Electrochemical Cell, 15mL (or BMM FC EC 15mL – Bottom Magnetic Mount Front Contact Electrochemical Cell, 15mL)
          1 x lid
          1 x glass chamber
          1 x bottom casing
          1 x sample mount
          1 x tantalum contact
          1 x plug
          1 x set of Nylon screws (screw variant only)
    1 x Reference electrode (Ag/AgCl, or Ag/Ag+), 70mm, 4 mm female banana socket
    1 x Metal Wire Auxiliary Electrode – 50HX15 0.6/250 mm, platinum 99.9%, 4 mm female banana socket

    Read more
  • Custom made glass products

    In cooperation with a glass company that manufactures custom glass electrochemical cells for BVT, we offer a unique opportunity to manufacture custom glass products according to customer requirements.

    This may include electrochemical flasks, cells, distillation columns and utility glass in dimensions and shapes that meet the customer’s requirements.

    Read more
  • Standard electrochemical cell setup (redox.me)

    This is a stationary solution standard electrochemical (electrolytic) cell for measurements of electrodes in a form of:

    a) rod/disc (6 mm dia.),

    b) thin film deposited on a flat substrate (using a sample holder) and

    c) free-standing membrane (using the basic sample holder).

     

    The workingcounter, and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. The cell has two spare ports for connection of e.g. thermometer, Clark electrode, pH meter electrode, or other 6 mm dia. electrode/probe. 

    The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. The jacketed model is available here

     

    Application note
    The reference electrode tip should be placed close to a working electrode center. This will ensure a low potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including metal wire and metal foil electrodes as well as graphite rod. The bubbling of gas through the solution must be stopped prior to experiment.

     

    Specification:
    maximum electrolyte volume: 100, 150, 200, 250, 350, 500 or 1000 mL
    electrode plug diameter: 6 mm
    number of electrode ports: 5
    vial material: borosilicate 3.3 glass

     

    Intrastat data:
    HS Code: 90309000
    Country of Origin: Sweden
    NET weight: 200 g (100, 150 mL), 300 g (200, 250, 350 mL), 400 g (500 mL), 600 g (1000 mL)

     

     
    Read more
  • TC4 Electrochemical Glass Cell

    Simple borosilicate glass cell serves for electrochemical measurements.

     

    The temperature of the analyzed solution can be controlled when placing the cell in MT1-1 minithermostat.

     

    Cell openings are designed for electrochemical sensors connector KA1.C, classical electrodes WCEc, ACEc, RCEc and stirrer ST1, ST3 separately.

    Read more
  • TC5 Electrochemical Glass Cell

    Borosilicate glass cell serves for electrochemical measurements. The cell is jacketed.

    The analyzed solution can be thermostated by external thermostat.

    Cell openings are designed for electrochemical sensors connector KA1.C, classical electrodes WCEc, ACEc, RCEc and stirrer ST1, ST3 separately.

    Read more
  • TC6 Electrochemical Glass Cell

    Borosilicate glass cell serves for electrochemical measurements.

     

    The analyzed solution can be thermostated by minithermostat MT1-1.

     

    Cell openings are designed for electrochemical sensors connector KA1.C, classical electrodes WCEc, ACEc, RCEc and stirrer ST1, ST3 separately.

     

    The device enables the measurement with inserted samples.

    Read more
  • TC7 Electrochemical Glass Cell

    The TC7 is a low cost Glass Cell that is ideal for students and basic lab measurements.

     

    The TC7 comes with a stand, specially designed for it, and the stand provides more stability and ease of use.

    The Borosilicate glass cell serves for electrochemical measurements. Cell openings are designed for the SPE Electrochemical Sensors Connector KA1.C,Classical Electrodes WCEc, ACEc, RCEc, STP1.*

    Stoppers for Cells, and Stirrer’s ST1 and ST3 separately.

    The device enables the measurement with inserted samples.

    Read more
  • TC9 Electrochemical Glass Cell

    Borosilicate glass cell serves for electrochemical measurements.

     

    The analyzed solution can be thermostated by external thermostat MT1-1.

     

    Cell openings are designed for stirrer ST9 or mini RDE and connector KA9.s with folder for electrochemical sensor AC9C, classical electrodes WCEc, ACEc and RCEc. The device enables the measurement with inserted samples.

    Read more