  • 2PP.M.T Dual Channel Peristaltic Pump

    The peristaltic pump 2PP10.M*.T* consists of miniature motor with planetary gear and stainless body of peristaltic pump. Optionally the motor is equipped with encoder. The pump has two channels. The flow is in one direction. The pump is designed for extremely small applications such as medical or military applications. It can be used in hand-held devices. The lifetime of tubing is optimized to maximal value. The pulsation is minimized for flow cell FC2. The device is supplied by USB connection with PC.

    Read more
  • 2PP.T Dual Channel Peristaltic Pump

    The peristaltic pump 2PP.T* is simple device for routine laboratory use. The pump has two channels. The flow is in one direction. The lifetime of tubing is optimized to maximal value. The pulsation is minimized for flow cell FC2.

    The integrated shaft enables fastening by standard laboratory clamps. The pump is supplied by max 12V. The rotation speed is controlled by voltage. The control unit is delivered with pump.

    The force on the tubing is adjusted by screw a spring. The pulsation damper can be ordered separately.

    Read more
  • AC1 Electrochemical sensor

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor. All sensors can be equipped with heating and temperature sensing elements. Thermistor (must be calibrated) or Pt 1000 (the response corresponds to the ISO standard) is used as the temperature sensor.

    Read more
  • AC1 Sw = 6.8 mm2 Electrochemical sensor

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor. All sensors can be equipped with heating and temperature sensing elements. Thermistor (must be calibrated) or Pt 1000 (the response corresponds to the ISO standard) is used as the temperature sensor.

    Read more
  • AC1.AChE Electrochemical sensor

    Amperometric Acetylcholinesterase three-electrode sensor with patented structure made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm 

    WE material: Pt

    Acetylcholinesterase from electric eel type VI-S is immobilized on the active surface of a working electrode of electrochemical sensor AC1.W2.RS (i.e. Platinum working electrode, silver reference electrode). The diameter of the immobilized bioactive membrane is 2 mm and the mean applied activity is 1 unit/mm2.

    Read more
  • AC1.GOD Electrochemical sensor

    Amperometric Glucose Oxidase three-electrode sensor with patented structure made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Pt

    Glucose Oxidase (GOD) from Aspergillus Niger is immobilized on the active surface of a working electrode of amperometric substrate AC1.W2.RS. The diameter of the immobilized bioactive membrane is 2 mm and the mean applied activity is 1 unit/mm2.

    Read more
  • AC13 Electrochemical sensor

    Amperometric  three-electrode longer version of AC1 made by thick film technology

    Dimensions: 50.8 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

    Read more
  • AC1P Electrochemical sensor

    Amperometric three-electrode sensor with patented structure type AC1 with polished working electrode made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. Working electrode has homogenous surface with roughness less than 1 µm. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

    Read more
  • AC2 Electrochemical sensor

    Amperometric two-electrode sensor with two working electrodes made by thick film technology.

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

    The sensor is formed on a corundum ceramic base. On to this surface two working electrodes, and one reference electrode are applied. The working and the auxiliary electrodes can be made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. Different bio-chemically active substance can be immobilised on the working electrode to create a biosensor.

    Read more
  • AC3 Electrochemical sensor

    Narrow amperometric single working electrode sensor made by thick film technology

    Dimensions: 50.8 x 2.54 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

    The sensor is formed on a corundum ceramic base. On to this surface the working electrode is applied. The working electrode is made of variety of materials. At the end of the sensor there is a contact which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor.

    Read more
  • AC4 Electrochemical sensor

    Amperometric single working electrode sensor with a extremely big working electrode made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

    The sensor is formed on a corundum ceramic base. On to this surface working electrode is applied. The working electrode is made of variety of materials. At the end of the sensor there is a contact which is connected with the active part by the silver conducting path which is covered by a dielectric protection layer.

    Read more
  • AC5 Electrochemical sensor

    Screen printed electrochemical array of 8 working electrodes

    Dimensions: 25.4 x 50.8 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

    The sensor is formed on a corundum ceramic base. On to this surface the working and the reference electrodes are applied. The working electrodes create an array of eight electrodes. The electrodes can be made of variety of materials (see below). At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrodes of the sensor.

    Read more
  • AC6 Electrochemical sensor

    Amperometric  three-electrode sensor with two auxiliary electrodes made by thick film technology

    Dimensions: 25.4 x 10.16 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and two auxiliary electrodes are applied. The electrodes can be made from variety of materials (see below). At the end of the sensor there is a contacting field. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor.

    Read more
  • AC8 Electrochemical sensor

    Amperometric sensor with 4 working electrodes made by thick film technology

    Dimensions: 50.8 x 8.47 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

    The sensor is formed on a corundum ceramic base. On to this surface four working electrodes are applied. Electrodes are made of variety of materials (see below). At the end of the sensor there is a contact. It is connected with the active part by the silver conducting path which is covered by a dielectric protection layer. Different bio-chemically active substances can be immobilised on working electrodes of the sensor.

    Read more
  • AC9C Electrochemical sensor

    Amperometric sensor with an array of 8 working electrodes and 1 common reference electrode made by thick film technology with integrated connector

    Dimensions: 59.0 x 12.7 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

    The sensor is formed on a corundum ceramic base. On to this surface eight working electrodes, and the reference electrode are applied. The electrodes can be made of variety of materials (see below). At the end of the sensor there is an integrated connector. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. Different bio-chemically active substances can be immobilised on the working electrodes of the sensor.

    Read more
  • AC9C Holder

    Holder for AC9C electrochemical sensor with an array of 8 working electrodes and 1 common reference electrode.  It is used for multi-analyte detection. Sensor holder fits in TC9 glass cell opening.