CC4 Electrochemical Sensor Cell
The sensor is formed on a corundum ceramic base. The structure consists of two platinum working electrodes (Pt WE) and an integrated Thermistor on the opposite side covered by a dielectric layer. This sensor is then integrated with a specialised cell to create the CC4.
Related products
-
AC13 Electrochemical sensor
Read moreAmperometric three-electrode longer version of AC1 made by thick film technology
Dimensions: 50.8 x 7.26 x 0.63 mm
WE material: Au/Pt, Au, Pt, Ag, C
The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.
-
FC4.TL.* PEEK Flow Cell
Read moreThe FC4.TL flow cell is made of PEEK. It has teflon endings permitting a fully compatible connection to chromatography tubing. The flow cell enables the use of sensors in a flow through arrangement. The flow arrangement is Thin layer cell “TL” for AC1, AC2, CC1, CC2 and CC3 sensors. The sensor is inserted into the slit of cell and tightened by closing of the door. The cell ensures the wall-jet flow around the working electrode and it is optimised so that no air bubbles cumulate in the cell. The cell contains also the contact and output cable.
-
STK Starting kit
Read moreStarting kit STK.S
Set of twenty electrochemical sensors to find the best one to fit your application
STK.RDE
Set of twenty electrochemical sensors to start your measurement with miniRDE
Starting kit is the set of twenty different electrochemical sensors to find the best one to fit your application. Starting kit contains 10 types of electrochemical sensors (2 sensors of each type), simple sensors connector and sensors box with numbered positions and silica gel.
-
AC5 Electrochemical sensor
Read moreScreen printed electrochemical array of 8 working electrodes
Dimensions: 25.4 x 50.8 x 0.63 mm
WE material: Au/Pt, Au, Pt, Ag, C
The sensor is formed on a corundum ceramic base. On to this surface the working and the reference electrodes are applied. The working electrodes create an array of eight electrodes. The electrodes can be made of variety of materials (see below). At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrodes of the sensor.