TS Testing Sensor

Simple identifier of electrochemical hardware error

Dimensions: 25.4 x 7.26 x 0.63 mm

 

Electrochemical measurements are very sensitive. Sometimes cables, connectors and their wetness can create the measurement errors. Testing sensor enables simple identification of electrochemical hardware error. The sensor has same geometry as AC1 type but its response produced by resistor. The response is stable and independent on chemistry. Testing sensor is formed on a corundum ceramic base. At the end of the sensor there is a contacting field which is connected with the SMD resistors by the silver conducting paths which are covered by a dielectric protection layer.

Useful Documents

TS Data Sheet

You may also like…

  • KA1.* Connector for Electrochemical Sensors

    The connector enables the use of the biosensor based on the substrates AC1, AC4, AC11, AC13, CC1, CC2 and TS1 in classical electrochemical arrangement.

    Read more
  • FC2.TL.* PMMA Flow Cell

    The flow cell enables the use of Screen printed sensors in a flow through arrangement.

     

    The flow cell is suitable for sensors of type AC1, AC2, CC1, CC2 and CC3.

     

    The Screen printed sensor is inserted into the slit of cell and tightened by closing of the door.  The cell ensures the wall-jet flow around the working electrode and it is optimised so that no air bubbles cumulate in the cell. The cell contains also the contact and output cable.

     

    With the sensors enclosed in a flow cell, it is possible to measure semi-automatically or automatically using a pump or liquid switch for sample supply. Under such conditions, maximum measurement reproducibility is ensured.

    Read more
  • KA4.* Connector for Electrochemical Sensors

    The connector enables the use of the electrochemical sensor/biosensor based on the substrates AC1, AC4, CC1, CC2 and TS1 in classical electrochemical arrangement. This connector has 6 contacts. Three contacts on the front side serve as contacts for 3-electrode system. Three contacts on the back side main purpose is to be used with AC1 (H, T) sensors that possess heating and temperature measuring termistor.

    Read more
  • PalmSens4

    The PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS).

     

    Compact, versatile and powerful

    • (Bi)Potentiostat / Galvanostat / Impedance Analyzer
    • FRA / EIS: 10 μHz up to  1 MHz
    • 9 current ranges: 100 pA to 10 mA
    • 18-bit resolution
    • Bluetooth or USB connection

     

    The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. The economical PalmSens4 is a complete laboratory instrument but its compact and rugged design makes it also ideal for field work.

    Connecting via Bluetooth guarantees a perfectly floating measurement.

     

    More information can be found through the link: https://www.palmsens.com/product/palmsens4/

     

    Configurable

    PalmSens4 comes in different configurations:

    • ±5 V or ±10 V potential range
    • EIS/FRA with maximum frequency of 100 kHz or 1 MHz
    • optional BiPotentiostat module for second WE
    • optional iR-Compensation

    Standard included

    • Rugged carrying case
    • High quality, double shielded cell cable with
      2 mm banana connectors for Working, Counter, Reference electrode and Ground
    • Crocodile clips
    • Dummy cell
    • USB cable
    • Manual and Quick Start document
    • PSTrace software for Windows

     

     
    Read more