AC9C Electrochemical sensor

Amperometric sensor with an array of 8 working electrodes and 1 common reference electrode made by thick film technology with integrated connector

Dimensions: 59.0 x 12.7 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 

The sensor is formed on a corundum ceramic base. On to this surface eight working electrodes, and the reference electrode are applied. The electrodes can be made of variety of materials (see below). At the end of the sensor there is an integrated connector. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. Different bio-chemically active substances can be immobilised on the working electrodes of the sensor.

You may also like…

  • PalmSens4

    The PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS).

     

    Compact, versatile and powerful

    • (Bi)Potentiostat / Galvanostat / Impedance Analyzer
    • FRA / EIS: 10 μHz up to  1 MHz
    • 9 current ranges: 100 pA to 10 mA
    • 18-bit resolution
    • Bluetooth or USB connection

     

    The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. The economical PalmSens4 is a complete laboratory instrument but its compact and rugged design makes it also ideal for field work.

    Connecting via Bluetooth guarantees a perfectly floating measurement.

     

    More information can be found through the link: https://www.palmsens.com/product/palmsens4/

     

    Configurable

    PalmSens4 comes in different configurations:

    • ±5 V or ±10 V potential range
    • EIS/FRA with maximum frequency of 100 kHz or 1 MHz
    • optional BiPotentiostat module for second WE
    • optional iR-Compensation

    Standard included

    • Rugged carrying case
    • High quality, double shielded cell cable with
      2 mm banana connectors for Working, Counter, Reference electrode and Ground
    • Crocodile clips
    • Dummy cell
    • USB cable
    • Manual and Quick Start document
    • PSTrace software for Windows

     

     
    Read more
  • KA9.s.* Connector for Electrochemical Sensor

    The connector enables the use of the electrochemical sensor AC9C or biosensor based on the AC9C substrate in classical electrochemical arrangement.

    Read more
  • TC9 Electrochemical Glass Cell

    Borosilicate glass cell serves for electrochemical measurements.

     

    The analyzed solution can be thermostated by external thermostat MT1-1.

     

    Cell openings are designed for stirrer ST9 or mini RDE and connector KA9.s with folder for electrochemical sensor AC9C, classical electrodes WCEc, ACEc and RCEc. The device enables the measurement with inserted samples.

    Read more
  • AC9C Holder

    Holder for AC9C electrochemical sensor with an array of 8 working electrodes and 1 common reference electrode. 

     

    It is used for multi-analyte detection. Sensor holder fits in TC9 glass cell opening.

    Read more