AC1. electrochemical sensor with a hydrophobic ring

Electrochemical sensor type AC1. with a hydrophobic ring – a hydrophobic layer is printed around the working electrode of the sensor (with a diameter of 1 or 2 mm), which ensures that the liquid applied to the working electrode of the sensor forms a drop and does not move outside to the reference and auxiliary electrodes (see the photograph below).

 

Such modification of the sensor is suitable, for example, before the next intended modification of only the working electrode of the sensor by the customer – for example, immobilization of a bioactive substance.

You may also like…

  • MSP Manual Screen Printer

    The manual screen printer is useful for applying of biochemical paste on electrochemical sensors. It may be used for preparing customer design electrochemical sensors also.

    It uses extremely small quantities of printing material. With the adjustment of the distance between the screen and the substrate the thickness of the printed elements can be varied. Under optimal conditions printing of lines with 200 µm can be achieved.

     

    * For this product, we recommend our customers use the Training Service from BVT.

    (https://bvt.cz/produkt/offer-of-long-term-automated-measurements-on-bvt-apparatus/)

    Read more
  • AC1P Electrochemical sensor

    Amperometric three-electrode sensor with patented structure type AC1 with polished working electrode made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. Working electrode has homogenous surface with roughness less than 1 µm. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

    Read more
  • AC1.GOD Electrochemical sensor

    Amperometric Glucose Oxidase three-electrode sensor with patented structure made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Pt

     

    Sensor Usage: Amperometric measurement of β-D-Glucose concentration in liquid samples (from 0 °C to 45 °C)

     

    Glucose Oxidase (GOD) from Aspergillus Niger is immobilized on the active surface of a working electrode of amperometric substrate AC1.W2.RS.

    The diameter of the immobilized bioactive membrane is 2 mm and the mean applied activity is 1 unit/mm2.

     

    * For this product, we recommend our customers use the Training Service from BVT.

    (https://bvt.cz/produkt/offer-of-long-term-automated-measurements-on-bvt-apparatus/)

    Read more
  • AC1.AChE Electrochemical sensor

    Amperometric Acetylcholinesterase three-electrode sensor with patented structure made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm 

    WE material: Pt

     

    Sensor Usage: Measurement of AChE inhibitor concentration – especially organophosphorous and carbamate pesticides (paraoxon, malaoxon), toxic and neurotoxic gases (sarin, soman, tabun, VX).

     

    Acetylcholinesterase from electric eel type VI-S is immobilized on the active surface of a working electrode of electrochemical sensor AC1.W2.RS (i.e. Platinum working electrode, silver reference electrode). The diameter of the immobilized bioactive membrane is 2 mm and the mean applied activity is 1 unit/mm2.

     

    * For this product, we recommend our customers use the Training Service from BVT.

    (https://bvt.cz/produkt/offer-of-long-term-automated-measurements-on-bvt-apparatus/)

    Read more