AC1P Electrochemical sensor

Amperometric three-electrode sensor with patented structure type AC1 with polished working electrode made by thick film technology.  

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Au

 

The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. Working electrode has homogenous surface with roughness less than 1 µm. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

You may also like…

  • TC6 Electrochemical Glass Cell

    Borosilicate glass cell serves for electrochemical measurements.

     

    The analyzed solution can be thermostated by minithermostat MT1-1.

     

    Cell openings are designed for electrochemical sensors connector KA1.C, classical electrodes WCEc, ACEc, RCEc and stirrer ST1, ST3 separately.

     

    The device enables the measurement with inserted samples.

    Read more
  • ST1.* Universal Stirrer for screen printed and classical electrodes

    • The universal stirrer ST1 uses a common  micro DC motor
    • ST1 allows the solution to be mixed and  the particles to be optimally transferred  to the surface of the printed or conventional electrodes.
    • The construction of stirrer assures the optimum mass transport with the minimum hydrodynamic noise.
    • The supply voltage 0 – 5 V and the maximum current of 450 mA mean that it can be used as a USB device.
    • The stirrer is manufactured from quality materials and suitable chemical measurements.
    • Revolutions range: 120 – 12 000 rpm
    View products
  • PalmSens4

    The PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS).

     

    Compact, versatile and powerful

    • (Bi)Potentiostat / Galvanostat / Impedance Analyzer
    • FRA / EIS: 10 μHz up to  1 MHz
    • 9 current ranges: 100 pA to 10 mA
    • 18-bit resolution
    • Bluetooth or USB connection

     

    The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. The economical PalmSens4 is a complete laboratory instrument but its compact and rugged design makes it also ideal for field work.

    Connecting via Bluetooth guarantees a perfectly floating measurement.

     

    More information can be found through the link: https://www.palmsens.com/product/palmsens4/

     

    Configurable

    PalmSens4 comes in different configurations:

    • ±5 V or ±10 V potential range
    • EIS/FRA with maximum frequency of 100 kHz or 1 MHz
    • optional BiPotentiostat module for second WE
    • optional iR-Compensation

    Standard included

    • Rugged carrying case
    • High quality, double shielded cell cable with
      2 mm banana connectors for Working, Counter, Reference electrode and Ground
    • Crocodile clips
    • Dummy cell
    • USB cable
    • Manual and Quick Start document
    • PSTrace software for Windows

     

     
    Read more
  • KA1.C.* Conic Connector for Electrochemical Sensors

    The connector enables the use of the biosensor based on the substrates AC1, AC4, AC11, AC13, CC1, CC2 and TS1 in classical electrochemical arrangement with stirred vessel. The cell TC4, TC5, TC6 is recommended for use with KA1.C.*.

    Read more