KA1.* Connector for Electrochemical Sensors

The connector enables the use of the biosensor based on the substrates AC1, AC4, AC11, AC13, CC1, CC2 and TS1 in classical electrochemical arrangement.

You may also like…

  • AC1 Electrochemical sensor

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer.

     

    A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor. All sensors can be equipped with heating and temperature sensing elements. Thermistor (must be calibrated) or Pt 1000 (the response corresponds to the ISO standard) is used as the temperature sensor.

     

     

    We also offer:

    • working electrode made of polished gold (WE diameter 1 or 2 mm) – sensor type: AC1P.W*.R*, with homogenous surface with roughness less than 1 µm
    • working electrode made of a material of guaranteed purity of up to 99.99 % (WE diameter 2 mm) – sensor type: AC1.GP

    We also offer activated graphite sensors on customer request.

    See activation example below:

     

    * Have a look at product cathegory Discounted SPEs – which include offer of Screen Printed Electrodes (SPEs) at a reduced Price from our AC1 line of Sensors. They are fully functional, but with visual defects or inconsistancies.

    – ideal for use by students to gain handling experience and knowledge on SPEs and their uses
    – ideal for initial experiments in research

    Read more
  • AC13 Electrochemical sensor

    Amperometric  three-electrode longer version of AC1 made by thick film technology

    Dimensions: 50.8 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

    Read more
  • AC4 Electrochemical sensor

    Amperometric single working electrode sensor with a extremely big working electrode made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface working electrode is applied. The working electrode is made of variety of materials. At the end of the sensor there is a contact which is connected with the active part by the silver conducting path which is covered by a dielectric protection layer.

     

    Read more
  • CC1 Electrochemical sensor

    A conductivity sensor made by thick film technology with interdigitated structure of electrodes

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. Onto this surface two interdigitated structures of electrodes are applied. The electrodes are made of Platinum-Gold alloy in standard product CC1.WS. At the end of the sensor there is a contact which is connected with the active part by the silver conducting path which is covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor.

    Read more