AC13 Electrochemical sensor

Amperometric  three-electrode longer version of AC1 made by thick film technology

Dimensions: 50.8 x 7.26 x 0.63 mm

WE material: Au/Pt, Au, Pt, Ag, C

 

The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

You may also like…

  • KA4.* Connector for Electrochemical Sensors

    The connector enables the use of the electrochemical sensor/biosensor based on the substrates AC1, AC4, CC1, CC2 and TS1 in classical electrochemical arrangement. This connector has 6 contacts. Three contacts on the front side serve as contacts for 3-electrode system. Three contacts on the back side main purpose is to be used with AC1 (H, T) sensors that possess heating and temperature measuring termistor.

    Read more
  • KA1.S.* Simple Connector for Electrochemical Sensors

    The connector enables the use of the biosensor based on the substrates AC1, AC4, AC11, AC13, CC1, CC2 and TS1 in classical electrochemical arrangement with stirred vessel.

    Read more
  • PalmSens4

    The PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS).

     

    Compact, versatile and powerful

    • (Bi)Potentiostat / Galvanostat / Impedance Analyzer
    • FRA / EIS: 10 μHz up to  1 MHz
    • 9 current ranges: 100 pA to 10 mA
    • 18-bit resolution
    • Bluetooth or USB connection

     

    The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. The economical PalmSens4 is a complete laboratory instrument but its compact and rugged design makes it also ideal for field work.

    Connecting via Bluetooth guarantees a perfectly floating measurement.

     

    More information can be found through the link: https://www.palmsens.com/product/palmsens4/

     

    Configurable

    PalmSens4 comes in different configurations:

    • ±5 V or ±10 V potential range
    • EIS/FRA with maximum frequency of 100 kHz or 1 MHz
    • optional BiPotentiostat module for second WE
    • optional iR-Compensation

    Standard included

    • Rugged carrying case
    • High quality, double shielded cell cable with
      2 mm banana connectors for Working, Counter, Reference electrode and Ground
    • Crocodile clips
    • Dummy cell
    • USB cable
    • Manual and Quick Start document
    • PSTrace software for Windows

     

     
    Read more
  • KA1.* Connector for Electrochemical Sensors

    The connector enables the use of the biosensor based on the substrates AC1, AC4, AC11, AC13, CC1, CC2 and TS1 in classical electrochemical arrangement.

    Read more