Category
- NEW PRODUCTS
- CUSTOMER SERVICES
- Custom made glass products
- Custom made and Modified Screen Printed Electrodes
- Sensors and electrodes
- Cables and connectors
- Cell
- Spectro, Photo, Raman – electrochemical cells
- Membrane Capacitive Deionization configurable cell
- NREL High-Pressure Low-Temperature Electrolysis Cell
- High-Pressure (25 bar) Single-Compartment Electrochemical Cell
- Stirrers
- Pumps
- Kits & Sets
- Minithermostat
- Modular PEM Electrolyzer Test Station
- Measurements of battery and supercapacitor materials
- Potentiostats
- Manual Screen Printer
- Accessories
- Discounted SPEs (at a reduced price with visual defects/inconsistancies, but fully functional)
ZIVE SP1 – potentiostat/galvanostat/ZRA
- Potentiostat/galvanostat/ZRA at affordable price
- Control voltage range: ±10V
- Control current range:9 ranges, 10nA~1A (10nA with gain)
Application
Features
Experimental Techniques Basic techniques
Advanced Software Package(Included)
|
| Power amplifier (CE) | |
| Power | 12Watt(12V@1A) |
| Compliance voltage | ±12V |
| Max. current | ±1A |
| Control speed selection | 4ea |
| Bandwidth | 2MHz |
| Slew rate | 10V/usec |
| Potentiostat mode(voltage control) | |
| Voltage control | |
| Control voltage range | ±10, ±1V, ±100mV |
| Voltage resolution | 16 bit per each range |
| Voltage accuracy | ±0.02% f.s(gain x1) |
| Max. scan range | ±10V vs. ref. E |
| Current measurements | |
| Current measurement range | 9 ranges (auto/manual setting) 10nA ~ 1A 10nA with gain |
| Current measurement resolution | 16 bit; 30uA, 3uA, 300nA, 30nA, 3nA, 300pA 30pA, 3pA (300fA with gain) |
| Current measurement accuracy | ±0.05% f.s.(gain x1)>100nA f.s. |
| Galvanostat mode(current control) | |
| Current control | |
| Current control range | max. ±1A ± full sacle depending on selected range |
| Current control resolution | 16 bit; 30uA, 3uA, 300nA, 30nA, 3nA,300pA 30pA, 3pA (300fA with gain) |
| Current control accuracy | ±0.05% f.s.(gain x1)>100nA. |
| Voltage measurements | |
| Voltage measurement range | 10V, 1V, 100mV |
| Voltage measurement resolution | 16 bit; 0.3mV, 30uV, 3uV |
| Voltage measurement accuracy | ±0.02% f.s(gain x1) |
| Electrometer | |
| Max. input voltage | ±10V |
| Input impedance | 2×1013Ω||4.5pF |
| Bandwidth | >22MHz |
| CMRR | >114dB |
| EIS(Internal FRA) for system | |
| Frequency range | 10uHz ~ 1MHz |
| Frequency accuracy | 0.01% |
| Frequency resolution | 5000/decade |
| Amplitude | 0.1mV ~ 5V rms (potentiostatic) 0.1 ~ 70% f.s. (galvanostatic) |
| Mode | Static EIS: potentiostatic, galvanostatic, pseudo-galvanostatic, OCP Dynamic EIS: potentiodynamic, galvanodynamic Fixed frequency impedance: potentiostatic, galvanostatic, potentiodynamic, galvanodynamic Multisine EIS: potentiostatic, galvanostatic Intermittent PEIS/GEIS |
| Main system | |
| PCcommunication | USB2.0 high speed |
| Line voltage | 100~240VAC, 50/60Hz, 1Amp |
| Power adapter | 24V 2.5Amp |
| Size/Weight | 160×329.4×83.3mm(WxDxH) / 2.5Kg |
| Max. output power | 12Watt |
| Software | |
| Max. steps per experiments | 1000 |
| Shutdown safety limits | voltage, current, power, AuxV etc. |
| Max. sampling rate | 2usec or 3usec depending on data point number |
| Min. sampling time | unlimited |
| Sampling condition | time, dv/dt, dI/dt, etc. |
| Interface for system | |
| Auxiliary port | |
| Auxiliary voltage input | 1 analog input: ±10V |
| Zero resistance ammeter | 100nA~1A range |
| External booster interface | via booster interface cable |
| System | |
| Cell cable | 1 meter shielded type (standard) working, reference, counter, working sense, Auxiliary V |
| Control DAC |
DSP with FPGA 2x16bit DAC(50MHz) for bias & scan |
| Data acquisition ADC |
2x16bit ADCs(500kHz) for voltage,current 1x16bit ADCs(250kHz) for auxiliary reading |
| Calibration | automatic |
| Filter selection | 4ea (5Hz, 1kHz, 500kHz, 5MHz) |
| Scan rate | 0~200V/sec in common mode 0~5000V/sec in fast mode |
| Max. channel number | 8 channesl via USB connection |
| Internal data memory | 542,000 points |
| PC requirement | |
| Operating system | Windows 7/8/10(32bit/64bit OS) |
| PC specification(minimum) | Pentium4, RAM 1GB or higher |
| Display | 1600×900 high color or higher |
| USB | high speed 2.0 |
| General | |
| Dummy cell | One external dummy cell included |
| Impedance analysis software | ZMANTM software |
| DC data analysis software | IVMANTM software package |
Thespecificationsaresubjecttochangewithoutnotice.
Related products
-
Basic Sample Holder – metal contact, 4 mm max. thickness (redox.me)
Read moreBasic Sample Holder with a metal contact works as an electrical conductor between an electrode material (free-standing or deposited on a substrate) and an external circuit. This holder consists of PEEK body, pure Tantalum, Stainless Steel 316L, Titanium, Copper or Nickel metal electrical contact, and PEEK screw to fix the electrode. It is compatible with most of inorganic and organic based plates, free-standing membranes or thin films deposited on flexible and rigid substrates. A maximum thickness of the sample is 4 mm. Tantalum is known to be inert to practically all organic and inorganic compounds. Tantalum’s corrosion resistance is very similar to that of glass, as both are unsuitable for use in hydrofluoric acid and strong hot alkali applications. Therefore, in those cases, we recommend the other wire contact variant. The metal contact can be fully immersed in the electrolyte.
Application note
Generally, the electrode is fabricated by fixing the electrochemical active sample into the holder using a screw. Such electrode is immersed in the ion-conducting solution as a working electrode or counter electrode. An electric current is passed between the working electrode and the counter electrode for a certain amount of time. Metal wire contact is permanently installed in the PEEK body. The holder is designed to be used multiple times. The holder should be cleaned prior to the installation of electrode material.Specification
holder body material: PEEK
rod diameter: 6 mm
contact material: Ta, SS 316L, Ti, Cu or Ni
contact wire diameter: 0.6 mm
contact wire total length: 110 mm
holder length: 70 mm
maximum sample thickness: 4 mmIntrastat data
HS Code: 90309000
Country of Origin: Sweden
NET weight: 100 gProduct includes
1 x Basic Sample Holder
1 x PEEK M3 screw
1 O-Ring (FKM for aqueous or FFKM for organic electrolytes) -
AC1.GP. Electrochemical sensor with a working electrode of guaranteed purity
Read moreBasic amperometric three-electrode sensor with patented structure made by thick film technology.
Dimensions: 25.40 mm x 7.26 mm x 0.63 mm
WE material: gold, platinum, silver, copper, iron, nickel, cobalt, chromium, tantalum, irridium, rhenium, magnesium, palladium, zirconium and others
*Selection of sensor electrode materials other than those listed above is possible upon agreement with the customer.
The sensor is made on a corundum ceramic base. Working, reference and auxiliary electrodes are applied to this surface. Working, reference and auxiliary electrodes are made of different materials. At the end of the sensor there is a contact field that is connected to the active part by silver conductive paths that are covered with a dielectric protective layer. The working electrode of the sensor with a diameter of 2 mm is made of a material of guaranteed purity of up to 99.99 % depending on the selected material– standard layer thickness 0.0125 mm.
We also offer a working electrode made of polished gold AC1P.W*.R*, with homogenous surface with roughness less than 1 µm.
We also offer activated graphite sensors on customer request.
-
ACEc.Pt plate Auxiliary Classic Electrode Conic with platinum plate
Read moreACEc.Pt plate is a glass tube with platinum plate of guaranteed purity 99.99 %. Standard connection is with a 2 mm banana plug. Auxiliary classic electrode with platinum plate (ACEc.Pt plate) is designed for electrochemical measurements.
Dimensions of Pt plate: 15 x 5 mm Pt
(Pt thickness approx. 0.21 mm)The size of the platinum sheet can be adjusted at the customer’s request.
-
USB Potentiostat Galvanoplot
Read moreUSB Potentiostat Galvanoplot is a super small, low-cost and affordable device suitable for dedicated volume applications, which is optimized for screen-printed sensor and biosensor applications. It can be used in many other research areas and with other electrochemical sensors, for corrosion measurement, battery and super-capacitors or fuel cells.
It is capable of performing all common Amperometric and Voltammetric electrochemistry protocols (CA, LSV, CV, DPV, NPV, SVW, GAL) and can be used with three electrode (WE/RE/CE) and two electrode (WE/RE-CE) setups. Plug the device directly into an Android mobile device through OTG port for a true on-site analysis experience. It is possible to choose from two types of interfaces allowing direct insertion of the BVT SPE sensors or the use of 3 classical electrodes with 2 mm banana plugs (WE, RE, CE).
Specifications
- Dimensions: 39x17x8 mm
- Weight: 5 g without sensor interface
- Voltage scan range: +-3V @1mV resolution
- Max current: 2000 nA (*at the request of the customer, it is possible to change the range, but this will change the resolution, noise and other parameters)
- Current resolution: 300pA@1KSPS/ 100pA@100SPS/ 30pA/10 SPS resolution
- Noise around: 50nA@1KSPS/ 7nA@100SPS/ 400pA/10 SPS
- Protocols: CA, LSV, CV, DPV, NPV, SVW, GAL
- Cell type: WE/RE/CE and WE/RE-CE
Connectivity: USB-C (Plug the device directly into an Android mobile device through OTG port for a true on-site analysis experience)
- Operating system compatibility: Windows 8, 10+
- Advanced analysis – filtering and auto peaks
Device Usage
- Electrochemical measurements
- Measurements with biosensors and electrochemical sensors
- Measurement of biochemical activity of a sample
- Corrosion measurement