TC4 Electrochemical Glass Cell

Simple borosilicate glass cell serves for electrochemical measurements.

 

The temperature of the analyzed solution can be controlled when placing the cell in MT1-1 minithermostat.

 

Cell openings are designed for electrochemical sensors connector KA1.C, classical electrodes WCEc, ACEc, RCEc and stirrer ST1, ST3 separately.

Useful Documents

TC4 Data Sheet

Category:

You may also like…

  • ST1.* Universal Stirrer for screen printed and classical electrodes

    • The universal stirrer ST1 uses a common  micro DC motor
    • ST1 allows the solution to be mixed and  the particles to be optimally transferred  to the surface of the printed or conventional electrodes.
    • The construction of stirrer assures the optimum mass transport with the minimum hydrodynamic noise.
    • The supply voltage 0 – 5 V and the maximum current of 450 mA mean that it can be used as a USB device.
    • The stirrer is manufactured from quality materials and suitable chemical measurements.
    • Revolutions range: 120 – 12 000 rpm
    View products
  • MT-1 Minithermostat

    Technical Parameters

    • Supply: 12 V
    • Min temperature: -9.9°C
    • Max temperature: 59.9 °C
    • For TC4, TC6 or Eppendorf microvials

    Device Usage

    • Cooling/heating of solution of temperature sensitive chemicals during experiments
    • Maintaining of chemicals at exact temperature
    • The electrochemical measurement with thermodiffusion
    • Heated electrodes technology

    The option with Eppendorf microvials 0.2 ml, 0.5 ml, 1.5 ml is possible

    Minithermostat device is designed for tempering an electrolytic bath for electrochemical measurements. The temperature is stabilized and the Peltier thermal element, which allows cool or warm the measured electrolytic samples.

    Read more
  • KA1.C.* Conic Connector for Electrochemical Sensors

    The connector enables the use of the biosensor based on the substrates AC1, AC4, AC11, AC13, CC1, CC2 and TS1 in classical electrochemical arrangement with stirred vessel. The cell TC4, TC5, TC6 is recommended for use with KA1.C.*.

    Read more
  • STP1.* Stoppers for Cells

    Stoppers are formed from white PBTP (Polybutylenterephtalate). They are used for covering of the glass cells produced by BVT.

     

    The system with the stopper is closed and space is prevent from solution evaporation.

    Model Recommended Vessel Termination
    STP1.S TC4, TC5, TC6 Stopper for TC4, TC5, TC6
    STP1.1 TC4, TC5, TC6 Stopper with bubbling
    STP1.2 TC4, TC5, TC6 Stopper with tubing
    STP1.3 TC4, TC5, TC6 Middle stopper
    Read more