  • AC1.W2.R1 (WE=2 mm) – batch no. 18620

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Pt

     

    Read more
  • AC1.W2.RS – batch no. 18509

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Pt

     

    Read more
  • AC1.W4.R1 (WE=2 mm) – batch no. 18510

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: C

     

    Read more
  • AC1.W4.R1 (WE=2 mm) – batch no. 18620

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: C

     

    Read more
  • AC1.W4.R1 (WE=2 mm) – batch no. 20B20

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: C

     

    Read more
  • AC1.W4.RS (WE=2 mm) – batch no. 18612

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: C

     

    Read more
  • AC1.WS.RS (WE=2 mm) – batch no. 18510

    Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Alloy of Gold and Platinum

     

    Read more
  • AC13 Electrochemical sensor

    Amperometric  three-electrode longer version of AC1 made by thick film technology

    Dimensions: 50.8 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

    Read more
  • AC1P Electrochemical sensor

    Amperometric three-electrode sensor with patented structure type AC1 with polished working electrode made by thick film technology.  

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and the auxiliary electrodes are applied. Working electrode has homogenous surface with roughness less than 1 µm. The working and the auxiliary electrodes are made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor to create a biosensor.

    Read more
  • AC2 Electrochemical sensor

    Amperometric two-electrode sensor with two working electrodes made by thick film technology.

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface two working electrodes, and one reference electrode are applied. The working and the auxiliary electrodes can be made of variety of materials. At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. Different bio-chemically active substance can be immobilised on the working electrode to create a biosensor.

    Read more
  • AC3 Electrochemical sensor

    Narrow amperometric single working electrode sensor made by thick film technology

    Dimensions: 50.8 x 2.54 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working electrode is applied. The working electrode is made of variety of materials. At the end of the sensor there is a contact which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor.

    Read more
  • AC4 Electrochemical sensor

    Amperometric single working electrode sensor with a extremely big working electrode made by thick film technology

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface working electrode is applied. The working electrode is made of variety of materials. At the end of the sensor there is a contact which is connected with the active part by the silver conducting path which is covered by a dielectric protection layer.

     

    Read more
  • AC5 Electrochemical sensor

    Screen printed electrochemical array of 8 working electrodes

    Dimensions: 25.4 x 50.8 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working and the reference electrodes are applied. The working electrodes create an array of eight electrodes. The electrodes can be made of variety of materials (see below). At the end of the sensor there is a contacting field which is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrodes of the sensor.

    Read more
  • AC6 Electrochemical sensor

    Amperometric  three-electrode sensor with two auxiliary electrodes made by thick film technology

    Dimensions: 25.4 x 10.16 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface the working, the reference and two auxiliary electrodes are applied. The electrodes can be made from variety of materials (see below). At the end of the sensor there is a contacting field. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor.

    Read more
  • AC8 Electrochemical sensor

    Amperometric sensor with 4 working electrodes made by thick film technology

    Dimensions: 50.8 x 8.47 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface four working electrodes are applied. Electrodes are made of variety of materials (see below). At the end of the sensor there is a contact. It is connected with the active part by the silver conducting path which is covered by a dielectric protection layer. Different bio-chemically active substances can be immobilised on working electrodes of the sensor.

    Read more
  • AC9C Electrochemical sensor

    Amperometric sensor with an array of 8 working electrodes and 1 common reference electrode made by thick film technology with integrated connector

    Dimensions: 59.0 x 12.7 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. On to this surface eight working electrodes, and the reference electrode are applied. The electrodes can be made of variety of materials (see below). At the end of the sensor there is an integrated connector. It is connected with the active part by the silver conducting paths which are covered by a dielectric protection layer. Different bio-chemically active substances can be immobilised on the working electrodes of the sensor.

    Read more