AC1.GOD Electrochemical sensor

Amperometric Glucose Oxidase three-electrode sensor with patented structure made by thick film technology

Dimensions: 25.4 x 7.26 x 0.63 mm

WE material: Pt

 

Sensor Usage: Amperometric measurement of β-D-Glucose concentration in liquid samples (from 0 °C to 45 °C)

 

Glucose Oxidase (GOD) from Aspergillus Niger is immobilized on the active surface of a working electrode of amperometric substrate AC1.W2.RS.

The diameter of the immobilized bioactive membrane is 2 mm and the mean applied activity is 1 unit/mm2.

 

* For this product, we recommend our customers use the Training Service from BVT.

(https://bvt.cz/produkt/offer-of-long-term-automated-measurements-on-bvt-apparatus/)

You may also like…

  • PalmSens4

    The PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS).

     

    Compact, versatile and powerful

    • (Bi)Potentiostat / Galvanostat / Impedance Analyzer
    • FRA / EIS: 10 μHz up to  1 MHz
    • 9 current ranges: 100 pA to 10 mA
    • 18-bit resolution
    • Bluetooth or USB connection

     

    The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. The economical PalmSens4 is a complete laboratory instrument but its compact and rugged design makes it also ideal for field work.

    Connecting via Bluetooth guarantees a perfectly floating measurement.

     

    More information can be found through the link: https://www.palmsens.com/product/palmsens4/

     

    Configurable

    PalmSens4 comes in different configurations:

    • ±5 V or ±10 V potential range
    • EIS/FRA with maximum frequency of 100 kHz or 1 MHz
    • optional BiPotentiostat module for second WE
    • optional iR-Compensation

    Standard included

    • Rugged carrying case
    • High quality, double shielded cell cable with
      2 mm banana connectors for Working, Counter, Reference electrode and Ground
    • Crocodile clips
    • Dummy cell
    • USB cable
    • Manual and Quick Start document
    • PSTrace software for Windows

     

     
    Read more
  • KA1.* Connector for Electrochemical Sensors

    The connector enables the use of the biosensor based on the substrates AC1, AC4, AC11, AC13, CC1, CC2 and TS1 in classical electrochemical arrangement.

    Read more
  • TC5 Electrochemical Glass Cell

    Borosilicate glass cell serves for electrochemical measurements. The cell is jacketed.

    The analyzed solution can be thermostated by external thermostat.

    Cell openings are designed for electrochemical sensors connector KA1.C, classical electrodes WCEc, ACEc, RCEc and stirrer ST1, ST3 separately.

    Read more
  • MT-1 Minithermostat

    Technical Parameters

    • Supply: 12 V
    • Min temperature: -9.9°C
    • Max temperature: 59.9 °C
    • For TC4, TC6 or Eppendorf microvials

    Device Usage

    • Cooling/heating of solution of temperature sensitive chemicals during experiments
    • Maintaining of chemicals at exact temperature
    • The electrochemical measurement with thermodiffusion
    • Heated electrodes technology

    The option with Eppendorf microvials 0.2 ml, 0.5 ml, 1.5 ml is possible

    Minithermostat device is designed for tempering an electrolytic bath for electrochemical measurements. The temperature is stabilized and the Peltier thermal element, which allows cool or warm the measured electrolytic samples.

    Read more