Category: Sensors and electrodes

Sensors and electrodes

Showing 17–32 of 41 results

  • ACEc Auxiliary Classic Electrode Conic

    ACEc is a glass tube with platinum plate wire.

     

    Standard connection is with a 2 mm banana plug. Auxiliary classic electrode (ACEc) is designed for measurements with thermostated cell TC4, TC5, TC6, TC9.

    Read more
  • CC1 Electrochemical sensor

    A conductivity sensor made by thick film technology with interdigitated structure of electrodes

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. Onto this surface two interdigitated structures of electrodes are applied. The electrodes are made of Platinum-Gold alloy in standard product CC1.WS. At the end of the sensor there is a contact which is connected with the active part by the silver conducting path which is covered by a dielectric protection layer. A bio-chemically active substance can be immobilised on the working electrode of the sensor.

    Read more
  • CC2 Electrochemical sensor

    A conductivity sensor with two active parts made by thick film technology with interdigitated structure of electrodes

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au/Pt, Au, Pt, Ag, C

     

    The sensor is formed on a corundum ceramic base. Onto this surface two interdigitated structures of electrodes are applied. The electrodes are made of Platinum-Gold alloy in standard product CC2.WS. At the end of the sensor there is a contact which is connected with the active part by the silver conducting path which is covered by a dielectric protection layer. A bio-chemically active substance can be put on the electrodes, one interdigitated structure, the second structure is reference.

    Read more
  • CC3.WSP Electrochemical sensor

    A conductivity sensor with two active parts made by sputtering with interdigitated structure of electrodes

    Dimensions: 25.4 x 7.26 x 0.63 mm

    WE material: Au

     

    The sensor is formed on a corundum ceramic base. Onto this surface two interdigitated structures of electrodes are applied. The electrodes are applied by sputtering. At the end of the sensor there is a contact which is connected with the active part by the gold conducting path which is covered by a polymer dielectric protection layer. A bio-chemically active substance can be immobilised on the electrodes, one interdigitated structure, the second structure is reference.

    Read more
  • CC4 Electrochemical Sensor Cell

    Conductometric sensor integrated with a specialised cell to create the CC4 Electrochemical Sensor Cell.

     

    The CC4 sensor is formed on a corundum ceramic base. The structure consists of two platinum working electrodes (Pt WE) and an integrated thermistor on the opposite side covered by a dielectric protection layer.

     

    Possible use of the CC4 sensor:

    • Quality control of distillation
    • Checking of waste waters from treatment plants, i.e. checking of Salt content

     

    Read more
  • CEc Calomel Electrode Conic

    The calomel electrode (CEc) is a reference electrode based on the reaction between elemental mercury and mercury(I) chloride.

     

    The aqueous phase in contact with the mercury and the mercury(I) chloride (Hg2Cl2, “calomel”) is a saturated solution of potassium chloride in water. The electrode is linked via a porous frit to the solution in which the other electrode is immersed. This porous frit makes liquid junction.

     

    Calomel electrode (CEc) is designed for measurements with thermostated cell TC4, TC5, TC6, TC9.

    Read more
  • Custom and Modified Screen Printed Electrodes (SPE)

    We offer our customers Modified and Custom Screen Printed Sensors based on their demands and needs, we will also recommend to the customer if there is a better option for their intended purposes.

     

    Examples of possible Modified SPE Surfaces

    Graphine, Streptavidin, Polyaniline and High-purity Materials.

     

    High-purity material on WE

    We can provide polished working electrode or insert a high-purity material on WE (99.9% or better).

    The WE can be applied also by sputtering.

     

    Materials of WE

    We can offer you not only standard materials as Au/Pt, Au, Pt, Ag, C (carbon) but also glassy carbon, Ni, Cu, and other materials.

     

    Special Active Surfaces

    We can provide SPEs with Special Active Surfaces using Copper (Cu), Nickle (Ni), Magnesium (Mg), Bismuth (Bi) and Zirconium (Zr). 

     

    Sensor/device size

    The Technological capabilities and our experience and knowledge enable us to produce devices from as small as 3 x 6 mm, up to as large as 150 x 1200 mm.

    Read more
  • Hanging Platinum Drop Electrode

    The Hanging Platinum Drop Electrode (HPDE) is solid phase alanogy of HMDE.

     

    The drop of liquid Pt at 2000 °C forms a drop of Pt. The surface of HPDE has nearly ideal surface which is impossible to obtain using polishing. HPDE has also spherical symmetry which enables mathematical treatment of its response.
    The material is not toxic and it is chemically stable. The only disadvantage is HPDE cleaning, which can be, however, in some cases solved by carefull insertion of the electrode tip to the flame of an alcohol burner.
    Thus HPDE can be used as reference electrode for complicated electrochemical studies, where it is necessary to distinguish the analytical signal from the signal generated by surface inhomogenities.

     

    Hanging platinum drop electrode (HPDE) is designed for measurements with thermostated cell TC4, TC5, TC6 and TC9.

    Read more
  • ISE Ion Selective Electrodes

    Ion Selective Electrodes, ISEs, are analytical tools widely used for potentiometric analysis of large scale of various ionic analytes.

     

    ISEs enable routine analysis in agriculture, food process, soil analysis, environmental anylysis, tribotechnical analysis, explosives and pyrotechnical mixtures analysis. They can be used for water, pot-, waste-, boiler-, mineral-, and well water samples.

     

    These electrodes allow for direct measurements of Ammonium, Lithium, Sodium, Calcium, Fluoride, Nitrate, Potassium and Barium.

     

    Electrodes are applicable to all commonly used measuring apparatus, with internal resistance of above 10^9 – 10^12 ohm.

    Diameter: 12 mm.

    Standard electrical connecting cable is 0.8 to 1 m. coaxial cable with BNC connector.

    The work with ion selective electrodes is time effective, requires an only small amount of chemicals, and a friendly price of measuring equipment MPH472.

    Read more
  • MAC Microreactor

    Microreactor for sensor used for measurement of small volume (20 µl) in closed system.

    Dimensions: 7.26 (width) x 0.63 mm (thickness)

     

    The MAC Microreactor is attached to the Sensor/s that the customer would like to use, and allows the customer to place a solution (20µl) for carrying out measurements directly above the WE in a contained area. The lid of the MAC Microreactor can be closed sealing the solution and helps avoid contaminants from affecting the test.

    Read more
  • Mini *-ISE-L60.C* Miniature ion selective elecrodes

     

    Miniature ion selective electrodes for potentiometric measurements of Chloride ions, Sodium ions, Calcium and Potassium ions concentration in aqueous solutions when used together with a reference electrode (following prior calibration) with a diameter of 6 mm and a length of 60 mm.

     

    Specifically, these applications may include analyses for agricultural purposes, online monitoring of the representation of selected ions in water management, certain industrial areas or agriculture (hydroponic cultivation of plants) etc.

     

    Electrodes are applicable to all commonly used measuring apparatus, with input resistance of at least 1012 Ω. The work with ion selective electrodes is time effective, requires an only small amount of chemicals, and a friendly price of measuring equipment (potentiostat with measuring method potentiometry).

     

    Possibility of integration with a FC.1ISE.1REF Flow cell for single ion selective electrode with integrated stirring – possible automation and continuous measurement.

     

    * For this product, we recommend our customers use the Training Service from BVT.

    (https://bvt.cz/produkt/offer-of-long-term-automated-measurements-on-bvt-apparatus/)

    Read more
  • Mini RCE.GEL.L60.C1 Miniature reference argentochloride gel electrode

    Miniature reference argentochloride gel electrode is designed for potentiometric measurements in connection with Miniature ion selective electrodes for potentiometric measurements of Chloride ions, Sodium ions, Calcium and Potassium ions concentration in aqueous solutions following prior calibration.

     

    The conductive connection of the internal electrolyte (KCl gel) enclosed in a plastic tube is mediated by a porous frit.

    Maintenance-free electrode – no need to top up the internal electrolyte (KCl gel).

     

    Electrodes are applicable to all commonly used measuring apparatus, with input resistance of at least 1012 Ω.

     

    Possibility of integration with a FC.1ISE.1REF Flow cell for single ion selective electrode with integrated stirring – possible automation and continuous measurement.

    Read more
  • Mini RDE tips

    Mini rotating disc electrode tips

     

    BVT provides a wide range of RDE tips, composed from different materials from gold, platinum and copper to glassy carbon and working electrode diameters from 2 to 5 mm.

    The electrode material is inserted into a body of the Rotating disk electrode (RDE) to ensure excellent chemical compatibility and mechanical integrity.

    Read more
  • Mini Rotating Disk Electrode

    The Mini Rotating disk electrode (Mini RDE) in general enables defined mass transfer towards electrode surface.

     

    The Mini RDE consists of the body of the RDE (motor) with 6 pcs of interchangeable electrode tips.
    The device is equipped by control electronics and SW and powered by USB connection with PC.
    Rotational speed of Mini RDE is 10 – 1300 rpm.

     

    RDE is suitable for measurements in glass cells of type TC4, TC5, TC6 and TC7. During measuring with RDE
    in a classic three-electrode connection, it is advisable to use a classic reference RCEc.R* and auxiliary electrode ACEc.

     

    * For this product, we recommend our customers use the Training Service from BVT.

    (https://bvt.cz/produkt/offer-of-long-term-automated-measurements-on-bvt-apparatus/)

    Read more
  • Mini Rotating Disk Electrode Kit

    The Mini Rotating disk electrode (RDE) in general enables defined mass transfer towards electrode surface.

     

    The Mini RDE consists of the body of the RDE (motor) with 6 pcs of interchangeable electrode tips for RDE. The device is equipped by control electronics and SW and powered by USB connection with PC. Rotational speed of Mini RDE is 10 – 1300 rpm.

     

    The Kit also includes:

    • TC4 electrochemical glass cell, which openings are suitable for included connector KA1.C.S
    • 20 pcs of Screen printed sensors (type AC1., AC2., AC4.)
    • classical reference electrode RCEc.

     

    During measuring with Mini RDE in a classic three-electrode connection, it is also advisable to use the classical auxiliary electrode ACEc.

     

    * For this product, we recommend our customers use the Training Service from BVT.

    (https://bvt.cz/produkt/offer-of-long-term-automated-measurements-on-bvt-apparatus/)

    Read more
  • OE.D*.E** Oxygen Electrode

    The Oxygen electrode consists of a PEEK body, platinum electrode, silver reference electrode and membrane holder.

     

    The platinum electrode is melted in glass. The membrane holder with electrolyte is attached by thread. Oxygen electrode (OE) is designed for measurements with thermostated cell TC4, TC5, TC6.

    Read more